Showing 1–10 of 16 results

  1. Fluke 1586A

    The 1586A Super‑DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, dc voltage, dc current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for benchtop sensor calibration in the lab.
    • Measure thermocouples, PRTs, thermistors, dc voltage, dc current, and resistance
    • Best-in-class temperature measurement accuracy
      • PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
      • Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
      • Thermistors: ± 0.002 °C
    • Input channels: Up to 40 isolated universal inputs
    • Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
    • Selectable scan speed: Up to 10 channels per second
    • Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
    • Real-time color trending: Chart up to four channels simultaneously
    • 6 1/2 digit display resolution for dc voltage, dc current, and resistance
    • Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
    • Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
    • Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
    • Data security: Administrator and user profiles for protecting settings and ensuring test traceability
    • Mx + B scaling and channel offset zero function
    • Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
    • Supported by TQSoft and TQAero thermal validation software for FDA 21 CFR Part 11 and AMS 2750 

    Remark  Please identify each quotation when ordering.
  2. Fluke 1620A

    The most accurate temperature and humidity graphical data loggers on the market

    The Fluke 1620A (DewK) thermo hygrometer and humidity monitor measures temperature to ± 0.125 °C and humidity to ± 1.5 % on two channels, and displays it on a big, clear screen. Ethernet, wireless (optional), or RS-232 will allow you to network as many Fluke 1620s (DewKs) as you’d like. And the LogWare III software will allow real-time logging of multiple Fluke 1620s (DewKs), data storage to your computer and seamless integration with MET/CAL® software.

    Thermo hygrometer features at a glance:

    • Superior accuracy
    • Network enabled
    • Powerful logging and analysis tools
    • Two interchangeable calibrated sensors
    • Huge memory
    • Upgraded software

    Remark  Please identify each quotation when ordering.
  3. Fluke 2271A

    Everything you need to calibrate and test pressure transmitters and gauges from very low pressure to 3000 psi (20 MPa), all in one box
           The Fluke Calibration 2271A Industrial Pressure Calibrator provides a complete, automated pressure testing solution for calibrating a wide variety of pressure gauges and sensors. Thanks to its modular design, it can be configured to meet different needs and budgets, and expanded to cover a broad workload.

           The 2271A is compatible with modules at two different accuracy classes, to provide maximum flexibility in workload and budget.  The PM200 modules provide 0.02% FS for most ranges (see specification tab for details).  The PM500 modules provide 0.01% Reading, allowing the 2271A to be used to test or calibrate higher accuracy transmitters and digital gauges.  
           The 2271A is ideal for calibration laboratories starting out in pressure calibration because it offers wide pressure measurement capabilities in a single instrument. Everything you need for calibrating pressure is included; just connect supply pressure. And your investment will stand the test of time: as your workload grows and changes, the 2271A can grow and change too. Just add measurement modules.  
           The 2271A automated pressure testing solution is also a great fit for labs that currently calibrate pressure transmitters and gauges and want to expand their capabilities or make their processes more efficient. This instrument is easy to set up and use, so you don’t have to reserve it for your most experienced technicians.  The built in electrical measurement and programmable tasks provide full automation, helping your lab run more efficiently.

    Remark  Please identify each quotation when ordering.
  4. Fluke 2638A

    Price-performance breakthrough in a stand-alone data acquisition system

    The Fluke Hydra Series III continues the Hydra Series legacy of precision, multi-channel data acquisition. The new Series III improves on Hydra's industry-leading thermocouple accuracy and adds a new dimension to how you collect and view data in a portable system. DC measurement accuracy of 0.0024 %, basic 0.5 °C thermocouple accuracy, full-color display, easy-to-use menu system and industrial safety ratings put the 2638A in a category of its own as a precision data acquisition system. The dedicated 6.5 digit digital multimeter (DMM) mode provides additional utility and value. The 2638A is expandable from 22 to 66 channels of differential analog inputs. A flexible, 22-channel Universal Input Connector lets you connect and disconnect any type of input to any channel, quickly and easily. Selectable inputs include dc voltage, ac voltage, resistance, thermocouple, RTD, thermistor, frequency and dc and ac current. You can also use the 2638A with optional software and other Fluke data loggers to create a flexible, customized data acquisition system with an almost unlimited number of channels.

    2638A Hydra Series III features at a glance

    • DC accuracy of 0.0024 %
    • Thermocouple accuracy of 0.5 °C
    • Up to 66 universal differential isolated inputs
    • On-screen color trend graphing of up to four channels at a time
    • Easy-to-use menu system for setup and data management
    • Input types: ac V, dc V, ac I, dc I, thermocouple, PRT (2, 3, 4 w), thermistor, resistance (2-4 w), frequency
    • Multi-channel real-time data display
    • 6.5-digit bench DMM function for front-panel inputs
    • Monitor function for real-time viewing and charting between scans
    • 20 on-board math channels
    • One-button screen capture of chart or data displays
    • 45 channels/second basic dc scan rate
    • Internal 57,000 scan/setup file memory
    • USB flash drive support
    • Data security features
    • 300 V CAT II input safety rated
    • Supported by TQSoft and TQAero thermal validation software for FDA 21 CFR Part 11 and AMS 2750 compliant data collection

    Remark  Please identify each quotation when ordering.
  5. Fluke 5128A

    Fast, portable humidity probe and logger calibration with accredited 1% RH system accuracy

     
    The Fluke Calibration 5128A RHapid-Cal Humidity Generator is a portable humidity generator for calibrating a large workload of probes in the laboratory or on-site in the field. It is used by corporate calibration/research labs and independent calibration labs where humidity measurement is critical to prevent spoilage of products in industries including pharmaceuticals, medical devices, semiconductors, chemicals, and food production.
    In the lab, the 5128A calibrates humidity probes 33% faster than a two-pressure generator. In the field, the 5128A provides more thorough, reliable multi-point calibrations than one-point spot checks using handheld humidity meters. The 5128A comes standard with an ISO 17025 accredited system calibration. Support offerings include online chat, email, phone, and product service from Fluke Calibration, channel partners and authorized service centers around the world.

    Key features

    • Best-in-class system accuracy for dependable humidity probe calibration
    • Rapid humidity and temperature stabilization time for high calibration throughput
    • Supports on-site, multi-point calibration of humidity probes
    • Versatile design accommodates a large workload
    • Compact size and lightweight for easy transport
    • ISO 17025 accredited system calibration included standard
    • Easy to maintain

    Remark  Please identify each quotation when ordering.
  6. Fluke 5502A

    Robust, transportable solution to match your workload and budget

    • Calibrates a wide variety of electrical test equipment
    • Robust protection circuits prevent costly damage from operator error
    • Ergonomically designed carrying handles make the 5502A easy to transport
    • Rugged carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
    • Current output that extends to 120 A when paired with the 52120A Transconductance Amplifier
    • Remarkably affordable

    Remark  Please identify each quotation when ordering.
  7. Fluke 5730A

    The new gold standard in electrical calibration

     Since 1988, the 5700A family has set the standard for multifunction calibrator performance in calibration laboratories around the world. Now the time has come to advance this best-in-class calibrator, taking advantage of twenty-first century technology and usability. The Fluke Calibration 5730A High Performance Multifunction Calibrator is the culmination of years of engineering development, customer research and industrial design, to bring to market the new “gold standard” in electrical multifunction calibration.

    High performance for the future

    Like its predecessors, the 5730A calibrates a wide range of digital multimeters, up to long-scale 8.5 digit DMMs, as well as RF voltmeters when equipped with the wideband option. But this new model features improved specifications that will help you increase test uncertainty ratios (TURs) and increase test confidence. What’s more, the improved specifications will reduce your need to guardband, giving you confidence and peace of mind in your calibrations.
    • Improved performance specifications for ac voltage, ac current and resistance
    • 6.5 inch VGA capacitive touch screen with full color graphical user interface
    • Visual Connection Management™ output terminals guide connections
    • Graphical user interface in nine languages
    • Compatible with 52120A and 5725A amplifiers
    • Full MET/CAL® compatibility with 5700A and 5720A procedures
    • Artifact Calibration using 10 V, 1 Ω and 10 kΩ external standards; 30 MHz and 50 MHz wideband output options available

    Remark  Please identify each quotation when ordering.
  8. Fluke 5790B

    Precision ac voltage and current measurements have never been this easy


         The 5790B AC Measurement Standard is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you would expect from a thermal transfer standard with the ease of use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ± 24 ppm (one year, 23 °C ± 5 °C). The 5790B is designed to meet the complete ac voltage, ac current and wideband verification requirements of the Fluke Calibration 5735A, 5720A, and 5700A Multifunction Calibrators; 5522A, 5502A, 5520A, and 5500A Multi-Product Calibrators; plus other calibrators, amplifiers like the 52120, 5725A and 5205A/5215A, and transfer standards and ac voltmeters.
         The 5790B covers an alternating voltage range of 600 μV to 1000 V, and a frequency range of 10 Hz to 1 MHz. Wideband voltage options extend frequency range to 30 or 50 MHz.      The 5790B in combination with the Fluke A40B Current Shunts now allow you to make direct, absolute or relative current measurements without the need to perform any calculations.
         The 5790B may be used alone as a measurement device or as a transfer standard when compared to an external dc source. In either case the normally tedious switching and calculations are performed automatically by the 5790B, and the resulting ac/dc difference is displayed directly on the easy-to-read 6.5-inch full-color capacitive touch screen display.

    Remark  Please identify each quotation when ordering.
  9. Fluke 6003A

    Three power phases in a single easy-to-use instrument

    The Fluke Calibration 6003A Three Phase Electrical Power Calibrator is the most cost-effective way to get the superior accuracy and performance of three independent phases in one instrument. It is an ideal solution for calibration laboratories, electronics manufacturers, electric utility meter shops, and other organizations that manufacture and maintain energy meters, power quality analyzers, and similar tools.

    Features at a glance

    • Three phases in a single instrument
    • Cost effective
    • Easy to use
    • Simulates dc or ac electrical power and energy in voltage range to 600 ac V or 280 dc V and current range to 30 A per phase or 90 A combined
    • Phase shift between voltage and current channels can be set from 0° to 359.99°
    • Specifications of ± 375 ppm for power and  0.01° for phase 
    • Current outputs can be isolated from ground by up to 450 V peak
    • Optional energy and power quality  capabilities
    • Built-in dc multimeter for transducer output measurement
    • Offers a high current adapter for applications needing from 30 A to  90 A of current

    Remark  Please identify each quotation when ordering.
  10. Fluke 6109A

    Calibrate more sanitary sensors at a time – with confidence

    The 6109A and 7109A baths calibrate most temperature sensor applications used in clean process manufacturing, including pharmaceutical bioreactors (-10 C to 100 °C), chemical reactors (200 °C), steam-in-place process (122 °C to 140 °C), autoclave sterilization (120 °C to 135 °C), food storage freezers (-25 °C), and food processing (0 °C to 220 °C). A large tank volume (112 mm square tank opening x 154 mm depth) lets you immerse up to four sanitary sensors at the same time. Calibrate a batch of odd shaped temperature sensors of varying lengths and diameters, and still have room for a reference thermometer. Fast heating and cooling times let you get the job done without spending a lot of time waiting for the bath to come to temperature and stabilize. Increase your sanitary sensor calibration throughput and decrease expensive production downtime. Excellent system display accuracy of ± 0.1 °C. Accuracy covers all sources of error including calibration uncertainty, stability, uniformity, and repeatability. NVLAP accredited calibration is included standard. Fluke Calibration’s high metrological standards and conservative specifications mean you can have confidence in the measurements you make with the 6109A and 7109A Portable Calibration Baths.

    Key features

    • Calibrate up to four tri-clamp sanitary sensors at the same time
    • Wide temperature ranges cover most process applications:
      • 6109A: 35 °C to 250 °C
      • 7109A: –25 °C to 140 °C
    • Excellent display accuracy of ±0.1 °C provides 4:1 test uncertainty ratio (TUR) for critical applications
    • Easy to transport up stairs and across catwalks
    • Stainless steel casing withstands harsh sterilizing chemicals and is rust proof
    • Easy to use and maintain

    Remark  Please identify each quotation when ordering.